Heat pumps,
sized to the building.

In shortSurveyed on the heat loss, designed around the emitters you actually have, and commissioned so it runs at the efficiency it was sold on.
01 · The short version

A heat pump is only as good as the system it is asked to heat.

It makes a lot of warm water rather than a little hot water. Put that into a house designed around a 70 degree oil boiler and radiators sized for it, and the house is cold and the running cost is worse than what you replaced. That is where most of the bad heat pump stories come from, and none of them are the fault of the unit.

So the survey comes first, the emitters and pipework get assessed honestly, and you are told what needs upgrading before anything is ordered.

02 · How the job runs

Five stages
01Heat loss surveyRoom by room, on the actual fabric of the building. Not a rule of thumb off the floor area or the old boiler rating.Stage 01
02System designFlow temperature, emitter sizes, pipe sizes, cylinder and controls, all worked out together rather than one at a time.Stage 02
03The honest quoteIncluding the radiators and pipework that need changing. If the building is not ready for one, you get told that instead.Stage 03
04InstallationUnit, cylinder, buffer if the design needs one, pipework, electrical connection and controls, with the disruption planned in advance.Stage 04
05CommissioningSet, balanced and run up under load, with the settings recorded and explained to you at the end rather than left on default.Stage 05
An air source heat pump outdoor unit with insulated flow and return
03 · Straight answers

Four things
worth knowing.

They work below zero. Output drops as it gets colder, which is why the design margin matters, but the unit does not stop.

Radiators usually grow. Not always all of them. The survey says which, and it is cheaper to hear it now.

Running cost depends on the design. A well designed system beats oil. A badly designed one loses to it. The difference is the flow temperature.

Some houses are not ready. If yours is one of them we will say so, and quote for the work that would make it ready instead.

04 · Servicing

Existing units, any installer
A blocked heat exchanger coil before cleaning
Annual

Clean, check, and set again

Coil and fan cleaned, condensate clear, refrigerant circuit checked on pressures and temperatures, filters and strainers cleared, system pressure and expansion checked.

An installed air source heat pump seen from the garden
Diagnostics

When it is running but costing too much

Usually the flow temperature, the weather compensation curve, or a system that was never balanced. Almost never the thing the owner has been told to replace.

A cylinder and renewed copper pipework
Hot water

Cylinders and legionella cycles

Coil sizing, reheat times and the weekly sterilisation cycle set correctly, so the hot water is not being made by the immersion heater without anybody noticing.